Visionneuse du contenu Web

Afficher le menu
Systèmes d'implants dentaires
Implants courts T3®

Implant Treatment Options for Vertical Height Deficiencies

The T3 Short Implant’s length and features are designed to provide an implant treatment option in some challenging clinical cases where the bone height is insufficient for standard length implants

The Clinical Challenge:
In areas with minimal bone height, providing implant treatment may require complex surgical procedures, such as:

• A sinus lift procedure in the maxilla

• Vertical ridge augmentation in the mandible due to the proximity to the mandibular nerve

Technologies spécifiques

Surface de l'implant T3
Surface d’implant sablée et mordancée à l’acide, d’une rugosité moyenne de 1,4 μm sur toute la longueur de l’implant.1

Contact os-implant initial (IBIC)
Les dimensions des instruments chirurgicaux et de l’implant court T3 créent des ostéotomies précises parfaitement adaptées à la forme de l’implant afin de permettre une bonne stabilité primaire.3

Implant/Abutment Clamping Force
Proprietary* Gold-Tite Surface lubrication allows the screw to rotate further, increasing clamping force and maximizing abutment stability.3

Platform Switching**
Le platform switching médialise la jonction implant-pilier, permettant la reconstitution de l'espace biologique et participant au maintien des niveaux osseux.4

Possibilités de
formation
Demande
Informations complémentaires


  • Brochures
  • Résumés cliniques
  • Manuels

ZB0002FR - Implants courts T3 - Implants & Instrumentation

ZB0133 - Liste des références bibliographiques des implants courts T3

ZBINST5000FR - Implant court T3 - Guide chirurgical de référence

ZBINSTMT3SFR - Manual chirurgical pour implant court T3®

1. Gubbi P†, Towse R†. Quantitative and Qualitative Characterization of Various Dental Implant Surfaces. Poster Presentation: European Association for Osseointegration, 20th Annual Meeting; October 2012; Copenhagen, Denmark.

2. Meltzer AM‡. Primary stability and initial bone-to-implant contact: The effects on immediate placement and restoration of dental implants. J Implant R.econstr Dent. 2009;1(1):35-41.

3 Byrne D, Jacobs S, O’Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J. Prosthodont. 2006 May–Jun;15(3):164-171.

4. Boitel N, Andreoni C, Grunder U‡, Naef R, Meyenberg K‡. A Three Year Prospective, Multicenter, Randomized-Controlled Study Evaluating Platform-Switching for the Preservation of Peri-implant Bone Levels. Academy of Osseointegration, 26th Annual Meeting: 2011 March 3-5; Washington DC. A Biomet 3i sponsored study.

† The authors conducted this research while employed at Biomet 3i.

‡ Drs Grunder, Meltzer and Meyenberg have or had, financial relationships with Zimmer Biomet Dental resulting from speaking engagements, consulting engagements and other retained services.

* Pre-clinical studies are not necessarily indicative of clinical results.

** Placement of a smaller diameter restorative component than the diameter of the implant seating surface.

Unless otherwise indicated, as referenced herein, all trademarks are the property of Zimmer Biomet; and all products are manufactured by one or more of the dental subsidiaries of Zimmer Biomet Holdings, Inc., and distributed and marketed by Zimmer Biomet Dental (and, in the case of distribution and marketing, its authorized marketing partners). For additional product information, please refer to the individual product labeling or instructions for use. Product clearance and availability may be limited to certain countries/regions. This material is intended for clinicians only and does not comprise medical advice or recommendations. This material may not be copied or reprinted without the express written consent of Zimmer Biomet Dental. ZB0002 REV B 05/18 ©2018 Zimmer Biomet. All rights reserved.