Dental Implant Systems
T3® Implants

Contemporary hybrid surface provided by complex multi-surface topography

  • Coarse And fine micron surface features create an average mean surface roughness value Of 1.4μm1

Seal integrity provided by a stable and tight implant/abutment interface

  • A stable, tight implant/abutment interface minimizes abutment micromotion and reduces potential microleakage.2

Integrated platform switching

  • Medializes the implant/abutment junction (IAJ) inward, creating a biologic width between connective tissue and the IAJ, helping to maintain bone levels.3

 

T3 Short Implant

The T3 Short Implant’s length and features are designed to provide an implant treatment option in some challenging clinical cases where the bone height is insufficient for standard length implants.

 

The Clinical Challenge: In areas with minimal bone height, providing implant treatment may require complex surgical procedures, such as:

  • A sinus lift procedure in the maxilla
  • Vertical ridge augmentation in the mandible due to the proximity to the mandibular nerve
SHOP ONLINE
Educational
Opportunities
Request
More Information
  • Brochures
  • Clinical Summaries
  • Manuals
  • Multimedia

ART1235 - T3 Ex. Hex Implant Brochure

ZB0001 - T3 ImplantBrochure

ZB0010 - T3 Implant Surface Characterization Comparison

ZB0002 - T3 Short Implant Brochure

ART1048 - Certain Implant System Ordering Information

INSTSUR - Biomet 3i - Certain & External Connection Surgical and Site Preparation Product Catalog

ART1220 - Dental Implant System Design and the Potential Impact on Long Term Aesthetics: A Review of the 3i T3 Tapered Implant

ART1205 - Dynamic Loading Fluid Leakage Characterization of Implants Systems

360_EN - EAO Effect of Abutment Screw Design on the Seal Performance of an External Hex Implant System Poster

ART1226 - JIRD Special Reprint - Mastering Aesthetics In Post Extraction Sites

ART1238 - JIRD - Suppliment Peri implant disease Implant surface Summaries of Select Scientific Publications

ZB0133 - T3 Short Implants Reference List

ZB0134_T3 Short Implants Clinical Guidelines

INSTSM - Biomet 3i Surgical Manual For Tapered and Parallel Walled Implants

INST974 - Quick Reference Subcrestal Surgical Protocol Certain Internal & External Hex Connection Parallel Walled Implants

INST972 - Subcrestal Tapered Implant Placement Protocol - Certain Internal & External Connection Parallel Walled Implants

INST1253 - T3 Clinical And Technical Insights Quick Reference

ZBINSTMT3S - T3 Short Implant Manual

ZBINST5000 - T3 Short Implant Quick Reference Surgical Guide_

Implant Supported Overdenture

  1. Gubbi P††, Towse R††, Quantitative and qualitative characterization of various dental implant surfaces. Poster Presentation P421: European Association For Osseointegration, 20th Meeting; October 2012; Copenhagen, Denmark. (http://www.biomet3i.com/Pdf/Posters/Poster_421_EAO_Final.pdf).
  2. Lazzara R.† Dental implant system design and the potential impact on long-term aesthetics: A review of the 3i T3 Tapered Implant. ART1193EU BIOMET 3i White Paper. BIOMET 3i, Palm Beach Gardens, Florida, USA. http://biomet3i.com/Pdf/EMEA/ART1193C_T3%20Implant_White_Paper_EU.pdf
  3. Lazzara RJ, Porter SS. Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Perio Rest Dent. 2006;26:9-17.

† Dr. Lazzara has a financial relationship with Biomet 3i LLC resulting from speaking engagements, consulting engagements and other retained services.
††Dr. Gubbi and Mr. Towse contributed to the above research while employed by Biomet 3i.

All references to Zimmer Biomet Dental contained herein refer to the dental subsidiaries of Zimmer Biomet Holdings, Inc. Unless otherwise indicated, as referenced herein, all trademarks are the property of Zimmer Biomet; and all products are manufactured, distributed and marketed by Zimmer Biomet Dental (and, in the case of distribution and marketing, its authorized marketing partners). Please note that not all products are available and registered in every country/region. Please check with a Zimmer Biomet Dental representative for product availability and additional information. Zimmer Dental products and Biomet 3i products may not be cross-compatible. Please refer to individual product labeling for compatibility information.